HP StorageWorks 2000 Modular Smart Array Reference Guide (481599-003, August 2008)

Appendix A SNMP Configuration 231
connUnitTable Includes the following objects as
specified by the FA MIB2.2 Spec
connUnitId Unique identification for this
connectivity unit
Total of 16 bytes
comprised of 8 bytes of the
node WWN or similar
serial number-based
identifier (for example,
1000005013b05211) with
the trailing 8 bytes equal to
zero
connUnitGlobalId Same as connUnitId
Same as connUnitId
connUnitType Type of connectivity unit storage-subsystem[11]
connUnitNumports Number of host ports in the
connectivity unit
Number of host ports
connUnitState Overall state of the connectivity
unit
online[2] or unknown[1],
as appropriate
connUnitStatus Overall status of the connectivity
unit
ok [3], warning[4],
failed[5], or unknown[1],
as appropriate
connUnitProduct Connectivity unit vendors
product model name
Model string
connUnitSn Serial number for this connectivity
unit
Serial number string
connUnitUpTime Number of centiseconds since the
last unit initialization
0 at startup
connUnitUrl Same as systemURL Same as systemURL
connUnitDomainId Not used; set to all 1s as specified
by the FA MIB2.2 Spec
0xFFFF
connUnitProxyMaster Stand-alone unit returns yes for
this object
yes [3] since this is a stand-
alone unit
connUnitPrincipal Whether this connectivity unit is
the principal unit within the group
of fabric elements. If this value is
not applicable, returns unknown.
unknown[1]
Table A-1 FA MIB 2.2 Objects, Descriptions, and Values (Continued)
Object Description Value