HP StorageWorks 2000 Modular Smart Array Reference Guide (481599-003, August 2008)

Appendix A SNMP Configuration 235
connUnitPortState State of the port hardware unknown[1], online[2],
offline[3], bypassed[4]
connUnitPortStatus Overall protocol status for the port unknown[1], unused[2],
ok[3], warning[4],
failure[5],
notparticipating[6],
initializing[7], bypass[8]
connUnitPortTransmitter
Type
Technology of the port transceiver unknown[1] for Fibre
Channel ports
connUnitPortModuleType Module type of the port connector unknown[1]
connUnitPortWwn Fibre Channel World Wide Name
(WWN) of the port if applicable
WWN octet for the port, or
empty string if the port is
not present
connUnitPortFCId Assigned Fibre Channel ID of this
port
Fibre Channel ID of the
port
All bits set to 1 if the
Fibre Channel ID is not
assigned or if the port is
not present
connUnitPortSn Serial number of the unit (for
example, for a GBIC). If this is
not applicable, returns an empty
string.
Empty string
connUnitPortRevision Port revision (for example, for a
GBIC)
Empty string
connUnitPortVendor Port vendor (for example, for a
GBIC)
Empty string
connUnitPortSpeed Speed of the port in KByte per
second (1 KByte = 1000 Byte)
Port speed in KByte per
second, or 0 if the port is
not present
connUnitPortControl Not supported invalid[2] for an SNMP
GET operation and not
settable through an SNMP
SET operation
Table A-1 FA MIB 2.2 Objects, Descriptions, and Values (Continued)
Object Description Value