TABLE E-1 Event Descriptions and Recommended Actions
Event
Code Event Type Description Recommended Action
1 Warning A disk drive in the specified vdisk
failed. The vdisk is online but not
fault tolerant. If a spare is present the
controller automatically uses the
spare to reconstruct the vdisk.
See “Disk Drive Errors and
Recommended Actions” on
page 300.
If dynamic spares is enabled,
replace the failed drive. The
system automatically
reconstructs the vdisk.
If dynamic spares is disabled and
no spare is available, replace the
failed drive and add it as a vdisk
spare to the critical vdisk.
3 Critical The specified vdisk is now offline. If
a spare is present the controller
automatically uses the spare to
reconstruct the vdisk.
If no spare is available, replace the
failed drive and add it as a vdisk
spare to the critical vdisk.
4 Informational A drive had an uncorrectable error
and the controller reassigned the