HP StorageWorks 2000 Modular Smart Array Reference Guide (481599-003, August 2008)

288 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008
168 Warning or
informational
The specified SES alert condition was
detected in the enclosure indicated.
Most voltage and temperature
errors and warnings relate to the
power-and-cooling module.
See “Power-and-Cooling Module
Faults and Recommended Actions”
on page 302.
169 Informational The specified SES alert condition has
been cleared in the enclosure
indicated.
This event is generated when the
problem that caused event 168 is
cleared.
170 Informational The last rescan indicates that the
specified enclosure was added to the
system.
171 Informational The last rescan indicates that the
specified enclosure was removed
from the system.
172 Warning The specified vdisk has been
quarantined because not all of its
drives are available. There are not
enough drives to be fault tolerant.
The partial vdisk will be held in
quarantine until it becomes fault
tolerant.
Ensure that all drives are latched
into their slots and have power.
During quarantine, the vdisk is
not visible to the host. If after
latching drives into their slot and
powering up the vdisk, the vdisk
is still quarantined, you can
manually remove the vdisk from
quarantine so that the host can
see the vdisk. The vdisk is still
critical.
When the vdisk has been removed
from quarantine, event 173 is
logged.
173 Informational The specified vdisk has been removed
from quarantine.
174 Informational A device firmware update has
completed.
175 Informational An Ethernet link has changed status
(up/down).
TABLE E-1 Event Descriptions and Recommended Actions (Continued)
Event
Code Event Type Description Recommended Action