HP StorageWorks 2000 Modular Smart Array Reference Guide (481599-003, August 2008)

294 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008
233 Warning The specified drive type is invalid
and not allowed in the current
configuration.
One or more drives are not allowed
for this platform. They have been
removed from the configuration.
(Some platforms are SAS- or
SATA-only). Replace the
disallowed drives with ones that
are supported.
234 Critical The specified snap pool is
unrecoverable and can therefore no
longer be used.
All the snapshots associated with
this snap pool are invalid and the
user may want to delete them.
However, the data on the master
volume can be recovered by
converting it to a standard volume.
235 Informational A non-disk SCSI device, such as an
EMP or partner controller, has
reported a check condition.
236 Informational A special shutdown operation has
started.
237 Informational A firmware update has started and is
in progress.
238 Warning An attempt to write license data
failed due to an invalid license.
Check the license for what is
allowed for the platform, make
corrections as appropriate, and
reinstall. If the license is invalid,
the write will fail.
239 Warning A timeout has occurred while
flushing the compact flash.
Cycle power and restart the system.
If the error persists, save the log
files and contact a service
technician.
240 Warning A failure has occurred while flushing
the compact flash.
Cycle power and restart the system.
If the error persists, save the log
files and contact a service
technician.
TABLE E-1 Event Descriptions and Recommended Actions (Continued)
Event