HP StorageWorks 2000 Modular Smart Array Reference Guide (481599-003, August 2008)

Appendix E Event Codes 295
241–242 Informational Compact flash status events generated
by the auto-write-through feature
whenever an environmental change
occurs. If an auto-write-through-
trigger condition has been met, write-
back cache is disabled.
243 Informational A new RAID enclosure has been
detected. This happens when a
controller FRU is moved from one
enclosure to another and the
enclosure detects that the midplane
WWN is different from the WWN it
has in its local flash.
244 Warning There is not enough space to expand
the specified snap pool.
Add more storage and retry the
operation.
245 Informational An existing disk channel target device
is not responding to SCSI discovery
commands.
Check the indicated target device
for bad hardware or bad cable, then
initiate a rescan.
246 Warning The coin battery is either not present,
or it is not properly seated, or it has
reached end of life. (The battery is a
battery backup for the real-time
(date/time) clock. In the event of a
power failure, the date and time will
revert to 1970 Jan 1 00:00:00.
The coin battery is on the controller
module. A service technician must
replace or reseat the battery.
247 Warning The FRU-ID SEEPROM for the
specified field replaceable unit (FRU)
cannot be read; FRU-ID data might
not be programmed. FRU-ID data
includes the worldwide name, SCSI
ID, and branding information.
A service technician can reprogram
FRU-ID data.
248 Informational A valid feature license was
successfully installed. See event 249
for details about each licensed
feature.
TABLE E-1 Event Descriptions and Recommended Actions (Continued)
Event
Code Event Type Description Recommended Action