HP StorageWorks 2000 Modular Smart Array Reference Guide (481599-003, August 2008)

50 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008
Setting the SNMP Event Table Filter
Your storage system supports a Simple Network Management Protocol (SNMP)
management information base (MIB) that includes a table of events that have
occurred on the system. You can filter the criticality of events that are included in
this table.
The filter is applied as events are put into the table. Changing the filter does not
affect events already recorded in the table; therefore, old events are reported even
though they might not meet the current filter criteria.
Note – The event table is held in memory and is not an externally accessible file.
For information on viewing the event log, see “Viewing the Event Log” on
page 171.
For more information about using SNMP, see Appendix A.
To set the SNMP event table filter:
1. Select Manage > General Config > LAN Configuration.
2. In the Advanced LAN Options panel, click Advanced Options.
The SNMP Event Table Configuration panel is displayed.
3. Set Event Table Filter to one of the following options:
Informational – Puts all events into the table. This is the default.
Warning – Puts warning and critical events into the table. It is recommended to
include warning and critical events in the table.
Critical – Puts only critical events into the table. Critical events are the most
severe.
4. Click Change SNMP Event Table Configuration.