Replacing the module
Step 1: Remove the failed module
Cease access to the module and disconnect the cable(s).
Then, lift the port-colored latch (1) on the failed module and pull the
module straight out of the chassis (2).
Step 2: Install the replacement module
Slide the replacement module into the chassis, until the module
clicks into place. Then, reconnect the cables.
Verifying module status
After installing the replacement Ethernet iSCSI module, verify that:
The status LED at the top of the module is solid green.
No new error messages are displayed on the LCD panel.
NOTE: Unread error log messages can cause the fault LED to
light. Delete all resolved error messages.
Returning the failed module
Follow the instructions shipped with the replacement.