HP Smart Array Controllers on HP ProLiant Servers User Guide

Component identification 27
1 Green LED 2 Amber LED Interpretation
Off
On A backup is in progress.
Flashing (1 Hz)
On A restore is in progress.
Flashing (1 Hz)
Off The capacitor pack is charging.
On
Off The capacitor pack has completed charging.
Flashing (2 Hz)
Alternating with
amber LED
Flashing (2 Hz)
Alternating with
green LED
One of the following conditions exists:
The charging process has timed out.
The capacitor pack is not connected.
On
On The flash code image failed to load.
Off
Off The flash code is corrupt.
FBWC module LEDs (P222, P420, P421, P721m, P822)
The FBWC module has three single-color LEDs (one amber and two green). The LEDs are duplicated on the
reverse side of the cache module to facilitate status viewing.
1 - Amber 2 - Green 3 - Green Interpretation
Off
Off Off The cache module is not powered.
Off
Flashing 0.5 Hz Flashing 0.5 Hz The cache microcontroller is executing from within its
boot loader and receiving new flash code from the host
controller.
Off
Flashing 1 Hz Flashing 1 Hz The cache module is powering up, and the capacitor
pack is charging.
Off
Off Flashing 1 Hz The cache module is idle, and the capacitor pack is
charging.
Off
Off On The cache module is idle, and the capacitor pack is
charged.
Off
On On The cache module is idle, the capacitor pack is charged,
and the cache contains data that has not yet been
written to the drives.
Off
Flashing 1 Hz Off A backup is in progress.
Off
On Off The current backup is complete with no errors.
Flashing 1 Hz
Flashing 1 Hz Off The current backup failed, and data has been lost.
Flashing 1 Hz
Flashing 1 Hz On A power error occurred during the previous or current
boot. Data may be corrupt.