HP StorageWorks SmartStart EVA Storage 3.0.1 release notes (T5505-96028, April 2009)

Allow HP Command View EVA time to gather information after a reboot
When HP SmartStart EVA Storage initiates a server reboot, HP Command View EVA and HP SmartStart
EVA Storage restart automatically. It is possible for you to advance through the HP SmartStart EVA
Storage application dialog boxes before all configuration information is available. Be sure to wait a
minute to allow HP Command View EVA to gather the requisite storage array information before
proceeding. Otherwise, you might need to return to the main menu and restart HP SmartStart EVA
Storage.
Troubleshooting the HP VDS Hardware Provider installation
When using HP SmartStart EVA Storage to provision storage to your server, you may receive the
following message:
The HP VDS Hardware Provider may not be installed properly.
If the installation of the VDS Hardware Provider was successful, verify the Fibre Channel switch zoning
using the guidelines provided in the HP StorageWorks SAN design reference guide.
Running HP SmartStart EVA Storage from a network share
To run HP SmartStart EVA Storage from the Intranet or Internet network share, the Intranet zone security
level must be set to Full Trust. Otherwise, the operation fails and A .NET Security Exception
has occurred error message is displayed.
To change the zone security level:
1. Select Control Panel > Administration Tools > Microsoft .NET 2.0 Framework Configuration to
run the .Net Framework Configuration utility (mscorcfg.msc).
A .NET configuration window opens.
NOTE:
This utility is not part of the .NET 2.0 Redistributable package. It is part of the .NET Framework
Software Development Kit (SDK). You can download an SDK for your system from the Microsoft
Download Center website: http://www.microsoft.com/downloads/browse.aspx?displaylang=en&
productID=363FAD1D-FC68-461A-B459-BE5D41B521B2.
2. Navigate to Console Root > .NET Framework 2.0 Configuration > Runtime Security Policy.
3. In the Tasks pane, click Adjust Zone Security.
A Security Adjustment Wizard window opens
4. Select Make changes to this computer, and then click Next.
5. Select Local Intranet, move the trust level slider to Full Trust, and then click Next.
6. Click Finish to exit the utility.
Javascript error message
After using HP SmartStart EVA Storage to install HP Command View EVA, a Javascript error messages
can appear when you attempt to run HP Command View EVA.
This can occur if your browser is not configured correctly.