SmartStart 8.70 Release Notes

Diagnostics 14
Limited Survey data in RILOE II
Description
Survey data viewed through RILOE II is limited.
No keyboard, mouse, or graphics diagnostics support for systems with 512 MB of system memory or
less installed
Description
Due to limited available memory on systems with less than 512 MB of system memory, keyboard,
mouse, and graphics tests have been disabled.
No Fibre Channel diagnostics support
Description
Fibre Channel PCI cards are identified, but testing and identification of attached storage devices are not
available at this time.
Certain devices are not available for testing when running HP Insight Diagnostics.
Description
Network Interface Controllers and CD-ROM drives cannot be tested.
Physical drives that are configured as part of a logical volume on non-Smart Array Controllers are not
diagnosable.
Description
HP Insight Diagnostics Diagnosis only supports physical drives that are configured as part of a logical
volume on HP Smart Array Controllers.
HP Insight Diagnostics notes
Diagnostics notes are usability issues, but are not considered problems.
RPM does not uninstall all diagnostics files.
Description
Uninstallation of HP Insight Diagnostics does not remove files generated when running diagnostics.
Workaround
Some files might be generated during the execution of HP Insight Diagnostics. Manually remove the
/opt/hp/hpdiags directory with the command rm -rf /opt/hp/hpdiags. By default Survey
capture XML files are not removed.
An incorrect PCI slot number is reported by a device.
Description
An incorrect PCI slot number might be reported by the SMBIOS and subsequently by HP Insight
Diagnostics.
Workaround
Update to the current system ROM, and then re-run HP Insight Diagnostics.
Array Controller memory size is reported incorrectly on some controllers.
Description