Brocade Fabric OS Troubleshooting and Diagnostics Guide - Supporting Fabric OS v7.0.0 (53-1002150-02, March 2012)

98 Fabric OS Troubleshooting and Diagnostics Guide
53-1002150-02
Equipment status
10
28: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0
29: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0
30: 664k 6.7k 0 0 0 0 0 0 6 0 0 1 2 0 0
31: 12 4 0 0 0 0 0 0 3 0 0 1 2 0 0
(output truncated)
The portErrShow command output provides one output line per port. See Table 19 for a description
of the error types.
Equipment status
You can display status for fans, power supply, and temperature.
NOTE
The number of fans, power supplies, and temperature sensors depends on the switch type. For
detailed specifications on these components, refer to the switch hardware reference manual. The
specific output from the status commands varies depending on the switch type.
Checking the temperature, fan, and power supply
1. Log in to the switch as user.
2. Enter the sensorShow command. Refer to the Fabric OS Command Reference for details
regarding the sensor numbers.
3. Check the temperature output.
Look for indications of high or low temperatures.
TABLE 19 Error summary description
Error type Description
frames tx Frames transmitted
frames rx Frames received
enc in Encoding errors inside frames
crc err Frames with CRC errors
crc g_eof CRC errors that occur on frames with good end-of-frame delimiters.
too shrt Frames shorter than minimum
too long Frames longer than maximum
bad eof Frames with bad end-of-frame delimiters
enc out Encoding error outside of frames
disc c3 Class 3 frames discarded
link fail Link failures (LF1 or LF2 states)
loss sync Loss of synchronization
loss sig Loss of signal
frjt Frames rejected with F_RJT
fbsy Frames busied with F_BSY