Brocade Web Tools Administrator's Guide - Supporting Fabric OS v7.0.0 (53-1002152-01, March 2012)

Web Tools Adminstrator’s Guide 131
53-1002152-01
Zone configuration and zoning database management
9
The configuration is renamed in the configuration database.
5. Select Zoning Actions > Save Config to save the configuration changes.
Cloning zone configurations
You must use Web Tools with the EGM license to perform cloning operations for zone
configurations; otherwise, access to this feature is denied and an error message displays.
To clone a zone configuration, perform the following steps.
1. Open the Zone Admin window as described in “Opening the Zone Admin window” on page 118.
2. Select the Zone Config tab.
3. Select the zone configuration you want to clone from the Name list.
4. Click Clone.
5. In the Copy An Existing Zone Config dialog box, enter a name for the copied zone and click OK.
The selected zone is copied from the Zone Admin buffer.
6. Select Zoning Actions > Save Config to save the configuration changes.
No changes were made to the effective configuration. You do not need to enable the
configuration.
Deleting zone configurations
To delete a zone configuration, perform the following steps.
NOTE
You cannot delete a enabled configuration.
1. Open the Zone Admin window as described in “Opening the Zone Admin window” on page 118.
2. Select the Zone Config tab.
3. Select the configuration you want to delete from the Name list and click Delete.
4. On the confirmation dialog box, click Yes. The selected configuration is deleted from the
configuration database.
5. Select Zoning Actions > Save Config to save the configuration changes.
Enabling zone configurations
Several zone configurations can reside on a switch at the same time, and you can quickly alternate
between them. For example, you might want to have one configuration enabled during the business
hours and another enabled overnight. However, only one zone configuration can be enabled at a
time.
When you enable a zone configuration from Web Tools, the entire zoning database is automatically
saved, and then the selected zone configuration is enabled.
If the zoning database size exceeds the maximum allowed, you cannot enable the zone
configuration. The zoning database summary displays the maximum zoning database size.