Brocade Web Tools Administrator's Guide - Supporting Fabric OS v7.0.0 (53-1002152-01, March 2012)

150 Web Tools Adminstrators Guide
53-1002152-01
Viewing LSAN zones
11
Every link has a default cost. For an EX_Port 1 Gbps, 2 Gbps, 4 Gbps, 8 Gbps, 10 Gbps, and 16
Gbps links, the default cost is 1000. For a VEX_Port, the default cost is 10000. If the cost is set to
0, the default cost are be used for that link.
To configure the FCR router port cost, perform the following steps.
1. Open the Switch View window.
2. Click FCR in the Manage section of the Tasks menu.
3. Click the EX_Ports tab.
4. Disable the EX_Port.
5. Click the Router Port Cost button.
Viewing LSAN zones
The LSAN Zones tab displays all the LSAN zones, in both a tabular and tree form. If FC-FC Routing is
disabled, the table and the tree node in this tab display only the LSAN zones present in the
backbone fabric.
For more detailed information about a specific LSAN zone, click a zone name in the table and then
click the View Details button in the task bar. You can also click the zone name in the tree on the left
side of the window.
The LSAN matrix is mapping of LSAN Zones with the edge fabric they are going to communicate
with. When an LSAN matrix is created in the backbone fabric, only the LSAN zones mapped in the
edge fabrics are displayed in the LSAN Zones tab.
Follow the procedure described in “Creating and populating zones” on page 125 to create LSAN
zones.
Viewing LSAN devices
The LSAN Devices tab displays information about the physical and proxy devices and displays these
devices in a tree on the left side of the window. (If FC-FC Routing is disabled, the tables and tree
nodes in this tab are empty.)
Click the LSAN Devices element in the tree to display a count of all the physical and proxy LSAN
devices. Note that this count is for all of the LSAN fabrics.
Click the Physical Devices or Proxy Devices element in the tree to see a detailed list of the physical
or proxy devices. Click the device name in the tree for more detailed information about a specific
device.
Configuring the backbone fabric ID
Web Tools automatically disables FC-FC Routing before setting the fabric ID. You should manually
enable FCR after setting backbone FID. However, you must first disable all of the EX_Ports before
you begin this operation. After the fabric ID is changed, you must re-enable these ports.