Brocade Web Tools Administrator's Guide - Supporting Fabric OS v7.0.0 (53-1002152-01, March 2012)

Web Tools Adminstrator’s Guide 43
53-1002152-01
System configuration parameters
3
5. Select or clear the check boxes to enable or disable the corresponding arbitrated loop
parameters.
6. Click Apply.
7. En a b l e t he sw i t c h as described in “Enabling and disabling a switch” on page 37.
Arbitrated loop parameters
Configure the following arbitrated loop parameters on the Arbitrated Loop subtab of the Configure
tab:
Configuring system services
You can enable or disable FCP read link status (RLS) probing for F_Ports and FL_Ports. It is
disabled by default.
To configure system services, perform the following steps.
1. Open the Switch Administration window as described in “Opening the Switch Administration
window” on page 33.
2. Disable the switch as described in “Enabling and disabling a switch” on page 37.
3. Select the Configure tab.
4. Select the System subtab.
5. Select the Disable RLS Probing check box to disable RLS probing.
-or-
Clear the check box to enable RLS probing.
6. Click Apply.
7. En a b l e t he sw i t c h as described in “Enabling and disabling a switch” on page 37.
Configuring signed firmware
When the firmware is downloaded to a device, the system can validate the firmware based on a
configuration setting. By default, the signed firmware download is not validated.
NOTE
During the first download, the system ignores the signed firmware. After the first download, the
public key is downloaded and then, in subsequent downloads, you can turn on the feature.
You can view the public key on the Firmware Download tab in the Switch Administration window.
Send Fan Frames Select this check box to specify that fabric address notification (FAN)
frames are sent to public loop devices to notify them of their node ID
and address.
Always Send RSCN Following the completion of loop initialization, a remote state change
notification (RSCN) is issued when FL_Ports detect the presence of
new devices or the absence of pre-existing devices. Select this check
box to issue an RSCN upon completion of loop initialization, regardless
of the presence or absence of new or pre-existing devices.