HP Storage Essentials SRM 6.0 User Guide for Enterprise Edition and Standard Edition SRM Software (July 2008)

Provisioning Manager552
11.Click OK.
Rules for Creating Host Security Groups
This section contains the following topics:
Host Security Groups on EMC CLARiiON and Sun 6130 Storage Systems” on page 553
Host Security Groups on LSI Storage Systems” on page 553
Host Security Groups on EMC Symmetrix Storage Systems” on page 554
Host Security Groups on HDS Storage Systems” on page 554
Host Security Groups on HP MSA Storage Systems” on page 555
Host Security Groups on HP EVA Storage Systems” on page 555
Host Security Groups on IBM Storage Systems” on page 555
Host Security Groups on Sun 6920 and 6940 Storage Systems” on page 555
Host Security Groups on Xiotech Storage Systems” on page 556
The management server now uses host security groups instead of LUN masking and LUN mapping.
With the introduction of host security groups, the management server has a new definition of
mapped for this release. Mapped refers to capacity that is accessible by one or more hosts external
to the array (aggregated capacity of volumes that are accessible from hosts external to the
subsystem).
The number of initiators allowed in the host security group depends on the type of storage system:
Table 137 Allowed Initiators in Host Security Groups
Storage System Allowed Initiators in Host Security Groups
EMC CLARiiON 0 or more initiators
LSI 0 or more initiators
HDS 0 or more initiators
HP EVA 0 or more initiators
HP MSA 1 initiator
IBM Only 1 initiator per host security group
Sun 35xx 1 initiator per host security group
Sun 6920 and 6940 Only 1 initiator per host security group
Sun 6130 0 or more initiators
Symmetrix 1 initiator for host security masking
Xiotech 1 initiator