HP Storage Essentials SRM 6.0 User Guide for Enterprise Edition and Standard Edition SRM Software (July 2008)

Provisioning Manager568
group, but the target host security group is deleted when the first command is completed, and the
second command returns an error.
If you need more time for HiCommand Device Manager to respond, you can increase the amount of
time the management server waits, by modifying the
cimom.provider.hds.ProvisioningTimeout property. To change the provisioning timeout
property:
1. Select Options > Storage Essentials > Manage Product Health, and then click Advanced in the
Disk Space tree on the management server.
2. Click Show Default Properties at the bottom of the page.
3. Copy the following text:
cimom.provider.hds.ProvisioningTimeout
4. Repeat step 1 to return to the Advanced page.
5. Paste the copied text into the Custom Properties box. How you paste the text depends on your
Web browser. If you are using Microsoft Explorer or Netscape Navigator, right-click the box and
select Paste.
6. Make any necessary changes in the Custom Properties box. Change the value of the
cimom.provider.hds.ProvisioningTimeout property. (Note that the value is in
milliseconds.) For example, assume you want the management server to wait an hour. You
would assign 3600000 to cimom.provider.hds.ProvisioningTimeout, since
3600000 milliseconds is one hour. For example:
cimom.provider.hds.ProvisioningTimeout
=3600000
7. Click Save.
Initiator Ports Cannot Be Used for Provisioning
Ports designated as an initiator on a storage system belonging to the HDS Freedom Storage™
Lightning 9900™ Series or Freedom Storage Lightning 9900V Series cannot be used for
provisioning. If you select one of these ports, you receive a message saying that provisioning failed
because the HiCommand Database was not refreshed. The management server does not support
provisioning for ports designated as initiators on these storage systems.
Mapping Issue on HDS 9900V Storage Systems
On HDS 9900V storage systems, if a host is already mapped to a volume and you try to map the
same host to a volume in another host storage domain, corresponding to the same port, it will fail.
However for HDS 9900, the host can be mapped to a volume in another host storage domain
corresponding to the same port.
A Default LUN Number Is Used Instead of a User-Specified One
When you create a LUN, the user-specified LUN is ignored. The LUN is created with the next
available default number.
Issues Specific to HP Storage Systems
This section contains the following topic:
Cannot Always Delete Selected Volume on MSA, page 569