HP Storage Essentials V5.1 Installation Guide Second Edition (Linux Release) (T4283-96055, November 2006)

Storage Essentials 5.1 Installation Guide 171
discovered as a target. On the System Protocol Settings page, provide the port number for the host
under the WBEM section.
Discovery from HP SE
If you change the port number, you must make the management server aware of the new port
number in the Add Address for Discovery page (Tools > Storage Essentials > Home >
Discovery > Setup > Add Address). In the IP Address/DNS Name field, type a colon and then
the port number after the IP address or DNS name, as shown in the following example:
192.168.1.2:1234
where
192.168.1.2 is the IP address of the host
1234 is the new port number
If you have already added the host to the discovery list (Tools > Storage Essentials > Home >
Discovery > Setup) on the management server, you must remove it and then re-add it. You cannot
have more than one listing of the host with different ports.
Additional Parameters
The following table describes additional parameters that can be specified in the
cim.extension.parameters file:
Rolling Over the Logs
Table 11 Parameters for CIM Extensions
Parameter Description
-user The user defined in this parameter must be a valid user for the
host. Only the user needs to be defined. The user name and
password are provided from the management server during
discovery. The user does not need to have root authority. A
colon separated list can be used to specify multiple users.
-credentials
<username from the
management server>
:<password>
The credentials defined by this parameter must match the
values entered from the management server during discovery.
They are not used as authentication on the host itself.
-agentnic
<ip address>
Restricts the CIM Extension on multihomed systems to listen only
on the designated IP address.
-mgmtServerIP
<ip address>
Restricts the CIM Extension to listen only to a specific
management server IP address.