HP Storage Essentials V5.1 Installation Guide Second Edition (Linux Release) (T4283-96055, November 2006)

Troubleshooting324
No Stitching for Brocade Switches with Firmware 3.2.0” on page 327
Link Between a Brocade Switch and a Host Disappears from the Topology” on page 328
Incorrect Topology Sometimes Displayed for CNT Switches” on page 328
Unable to Find Elements on the Network” on page 328
Device Locking Mechanism for Brocade Element Manager Query/Reconfiguration” on
page 328
A Discovered Sun StorEdge A5000 JBOD Does Not Display Its WWN Properly” on page 328
Unable to Monitor McDATA Switches” on page 329
Unable to Detect a Host Bus Adapter” on page 329
Navigation Tab Displays Removed Drives as Disk Drives” on page 329
Unable to Obtain Information from a CLARiiON Storage System” on page 329
Discovery Fails Too Slowly for a Nonexistent IP Address” on page 330
“CIM_ERR_FAILED” Message” on page 330
Communicating with HiCommand Device Manager Over SSL” on page 332
Unable to Discover a UNIX Host Because of DNS or Routing Issues” on page 333
About the Topology
The software determines the topology by looking at the following:
Fibre channel switch The fibre channel switch contains a list of all elements within the fabric.
The software obtains a detailed listing of all elements connected to the switch fabric.
A host containing a Host Bus Adapter (HBA) All fibre channel host adapters look for
available elements attached to the HBA. This information is gathered by CIM Extensions and
sent to the management server.
Table 13 Troubleshooting Discovery and Discovery Data Collection/Get Details
Scenario Description What to do
The host appears discovered
and it is connected to the
switch.
The software is aware of the
host, but it cannot obtain
additional information about it.
Verify that a CIM Extension is
installed on the host.
Discovery from HP SIM
Discover the host again in HP
Systems Insight Manager. Then,
run Discovery Data Collection.
Discovery from HP SE
Try discovering the element
again in HP SE. Then, run Get
Details.