13 - 16
Failover 5100 Info Failover completed for %1. No action required.
5101 Info IP address %1 with subnet mask %2 was
added to target machine's %3 adapter.
No action required.
5102 Warning %1 has reached a failover condition. A
response from the user is required before
failover can take place.
User intervention has been configured.
Open the Failover Control Center and
accept or decline the failover prompt.
5103 Info Started adding drive shares from %1 to %2. No action required.
5104 Info %1 drive shares were taken over by %2. No action required.
5105 Info Attempting to run the %1 script. No action required.
5106 Success The %1 script ran successfully. No action required.
5107 Error Error occurred in running %1 script. Verify that the script identified exists with
the proper permissions.
5108 Error The source machine %1 is not responding
to a ping.
This occurs when all monitored IP
addresses on the source machine stop
responding to pings. Countdown to
failover will begin at the first occurrence
and will continue until the source machine
responds or until failover occurs.
5109 Error The public NIC on source machine %1 is
not responding to a ping.
The failover target did not receive an
answer to its ping of the source machine.
Eventually, a failover will result. Investigate
possible errors (down server, network
error, etc.).
Monitoring 5300 Info The following IP address was added to
target's monitoring list: %1
No action required.
5301 Info The following IP address was removed
from target's monitoring list: %1
No action required.
5302 Info Drive share information for %1 has been
updated on the target machine.
No action required.
NSIPHDriver 9000 Error Could not allocate memory for storing
registry path
Reboot the server and contact technical
support if this event occurs again.
9001 Error Thread creation failed Reboot the server and contact technical
support if this event occurs again.
9002 Error Could not allocate memory for parameter
key
Reboot the server and contact technical
support if this event occurs again.
9003 Error Could not read PlaceHolderCount from
the NSIPH Parameters key
Reboot the server and contact technical
support if this event occurs again.
9004 Error Could not allocate buffer to hold initial IP
address list for adapter
Reboot the server and contact technical
support if this event occurs again.
9005 Error Could not allocate buffer to hold initial
subnet mask list for adapter
Reboot the server and contact technical
support if this event occurs again.
9006 Error Could not read registry value for IP
address list or subnet mask list for adapter
Reboot the server and contact technical
support if this event occurs again.
9007 Error Could not write registry value for IP
address list for adapter
Reboot the server and contact technical
support if this event occurs again.
Category ID Severity Message Required Response