HP StorageWorks Storage Mirroring Scripting Guide (T2558-96327, April 2009)

16 - 13
Failback
Failover
Command FAILBACK
Description Initiates the failback process for the specified monitor machine
Syntax
FAILBACK <monitor> [ON <target>] REMONITOR|NOREMONITOR
Options
monitor—Name of the source machine designated as the monitor
target—Name of the target, an IP address on the target, or a virtual IP
address
REMONITOR—Automatically continues monitoring the source machine
after failback
NOREMONITOR—Automatically discontinues monitoring the source
machine after failback.
Examples
failback alpha on beta remonitor
Notes Options that contain non-alphanumeric characters must be enclosed in
quotation marks.
Command FAILOVER
Description Manually initiates the failover process for the specified monitor machine
Syntax
FAILOVER <monitor> [ON <target>] [APPLY | DISCARD | REVERT]
Options
monitor—Name of the source machine designated as the monitor
target—Name of the target, an IP address on the target, or a virtual IP
address
APPLY—Apply the data that is in the target queue before beginning
failover
DISCARD—Discard the data that is in the target queue and begin failover
immediately
REVERT—Revert the target to the last known good Storage Mirroring
state
Examples
failover alpha on beta apply
Notes If failover is configured for manual intervention, you must open the Failover
Control Center to access the intervention prompt.