HP StorageWorks Storage Mirroring for Linux User's Guide (T2558-96078, February 2008)

A - 29
Schedule Start
Schedule Window
Command SCHEDULE START
Description Sets criteria to start the transmission of data from the source to the target
Syntax
SCHEDULE <target_machine> START [STARTTIME = <mm/dd/yy> <hh:mm>] [MEMLIMIT =
<percent>]
[QUEUESIZE = <bytes>] [EVERY <number> <time_units>]
Options
target_machine—Name of the target machine
mm/dd/yy—Date in month/day/year format indicating when the transmission will begin
hh:mm—Time in hour:minute format using the 24 hour clock indicating when the transmission
will begin
percent—Any number between 0 and 100 indicating the percentage of the disk queue and system
memory that must be in use to initiate the transmission process
bytes—Number of bytes that must be in the source queue and system memory to initiate the
transmission process
number—Any number indicating how often the transmission process will be repeated
time_units—Minutes (min), hours (hr), or days (day)
Examples
schedule jersey start starttime=3/11/07 03:30
schedule philly start queuesize=400000
schedule jersey start starttime=3/03/07 18:00, every 8 hr
schedule philly start memlimit=25, queuesize=150000000
Notes The start option EVERY cannot be used by itself and cannot be the first option in a string of
options.
If you use more than one start option, the transmission will begin when the first start option
value is met. Additionally, each option after the first must be separated by a comma, as illustrated
in the Examples.
Machine names that contain non-alphanumeric characters must be enclosed in quotation marks.
Command SCHEDULE WINDOW
Description Sets criteria to only allow transmissions during a certain period of time
Syntax
SCHEDULE <target_machine> WINDOW <hh:mm> TO <hh:mm>
Options target_machine—Name of the target machine
hh:mm—Time in hour:minute format using the 24 hour clock. The first time is when the
transmission will begin and the second time is when the transmission will end.
Examples
schedule jersey window 23:00 to 06:00
Notes Establishing a transmission window by itself is not sufficient to start a transmission. You will need
to specify a start criteria.
Machine names that contain non-alphanumeric characters must be enclosed in quotation marks.