HP StorageWorks XP24000 Audit Log User and Reference Guide, v01 (AE131-96003, June 2007)

DescriptionItem
Indicates whether the Fabric switch is enabled or disabled.Fabric
Enable: Enabled, Disable: Disabled
The connecting mode of the Fabric switch selected.Connection
FC-AL: FC-AL is selected, P-to-P: P-to-P is selected
The number of ports where the topology of Fibre Channel is set.Num. of Ports
Install - Set Host Mode Operation
user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00,[Install],Set Host Mode,,Normal end,,,Seq.=xxxxx
+{Port,HostGrpID,Mode,option[0:31],Option[32:63],Option[64:95]}=[{XX,0xXXX,
0x00,0xXXXXXXXX,
0xXXXXXXXX,0xXXXXXXXX},{XX,0xXXX,0x4F,0xXXXXXXXX,0xXXXXXXXX,0xXXXXXXXX}],
Num. of Host Groups=2
[Install]
Install function
Set Host Mode
Set Host Mode operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in the following table.
Table 75 Detailed Info: Set Host Mode Operation
DescriptionItem
The name of the port where the host group is created.Port
The host group number.HostGrpID
The host mode set. Please see the HP StorageWorks XP24000 LUN Manager User's
Guide for the meaning of the host mode number.
Mode
The host mode option set. Hexadecimal values are output. See Table 118 for the relation
of output values and host mode option.
Option[0:31]
Option[32:63]
Option[64:95]
The number of host groups that the host mode setting is changed.Num. of Host
Groups
Sample Audit Logs100