HP StorageWorks XP24000 Audit Log User and Reference Guide, v01 (AE131-96003, June 2007)

Detailed information displays for this operation, as shown in the following table.
Table 87 Detailed Info: Uninstall Operation (Uninstalling a Shared Memory Module)
DescriptionItem
The mounting location of the PCB for shared memory.SM
The slot position of the shared memory module.Slot
The capacity of the cache memory module.Size
The number of shared memory modules.Num of SMMs
The flags of the options.PP Flag
The number of the flags of the options.Num of PP Flags
The maximum number of CUs.Max Number of
CUs
The mounting location of the batteryBattery
Indicates the installation or the uninstallation of the battery.Define
Install: Install battery, Uninstall: Uninstall battery.
The number of batteries.Num. of Batteries
NOTE:
Only the changed items will be output.
Example 5 (uninstalling a power supply)
user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00,[Install],Uninstall,,Normal end,,,Seq.=xxxxx
+Redundant Power Supply=[CL Additional Power Supply,CL Additional Power Supply2],
Num. of Redundant Power Supplies=2
[Install]
Install function
Uninstall
Uninstall operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Sample Audit Logs112