HP StorageWorks Storage Mirroring for Linux User's Guide (T2558-96317, June 2009)

15 - 17
5108 Failover Error The source machine %1 is
not responding to a ping.
This occurs when all
monitored IP addresses on
the source machine stop
responding to pings.
Countdown to failover will
begin at the first occurrence
and will continue until the
source machine responds or
until failover occurs.
5109 Failover Error The public NIC on source
machine %1 is not
responding to a ping.
The failover target did not
receive an answer to its ping
of the source machine.
Eventually, a failover will
result. Investigate possible
errors (down server, network
error, etc.).
5200 Failback Info.. Failback completed for %1. No action required.
5201 Failback Info.. IP address %1 was removed
from target machine's %2
adapter.
No action required.
5202 Failback Error Unable to Failback properly
because IP address %1 was
missing a corresponding
SubNet Mask.
Contact technical support.
5300 Monitoring Info. The following IP address was
added to target's monitoring
list: %1
No action required.
5301 Monitoring Info. The following IP address was
removed from target's
monitoring list: %1
No action required.
5302 Monitoring Info. Drive share information for
%1 has been updated on the
target machine.
No action required.
5500 Service Warning Could not connect to e-mail
server. Check to make sure
the SMTP server %1 is
available (error code: %2).
Storage Mirroring could not
connect to your SMTP server
or the username and/or
password supplied is
incorrect. Verify that SMTP
server is available and that
you have identified it
correctly in your e-mail
notification configuration.
Also verify that your
username and password
have been entered correctly.
5501 Service Warning E-mail notification could not
be enabled (error code: %1).
This alert occurs if there is an
unexpected error enabling
e-mail notification during
daemon startup. Check to
see if any other errors
related to e-mail notification
have been logged. Also,
check to make sure the
Windows Management
Instrumentation (WMI)
daemon is enabled. If neither
of these apply, contact
technical support.
ID Category Severity Event Message Required Response