Brocade Access Gateway Administrator's Guide - Supporting Fabric OS v5.2.1 (53-1000430-01)

Access Gateway Administrator’s Guide 2-5
Publication Number: 53-1000430-01
Enabling Access Gateway mode
2
To enable Access Gateway mode from the CLI
1. Connect and log in to the switch.
2. Enter the switchShow command to display the current switch configuration.
The example below shows a switch in the Fabric OS Native mode (where switchMode equals
Native).
3. Enter the switchDisable command to disable the switch.
4. Enter the ag --modeEnable command to enable Access Gateway mode.
The switch automatically reboots and comes back online in Access Gateway mode using a factory
default F_Port to N_Port mapping. See Appendix A, “Default Port Mapping”.
switch:admin> switchshow
switchName: switch
switchType: 43.2
switchState: Online
switchMode: Native
switchRole: Principal
switchDomain: 1
switchId: fffc01
switchWwn: 10:00:00:05:1e:03:4b:e7
zoning: OFF
switchBeacon: OFF
Area Port Media Speed State Proto
=====================================
0 0 -- N4 No_Module
1 1 cu N4 Online F-Port 50:06:0b:00:00:3c:b7:32
2 2 cu N4 Online F-Port 10:00:00:00:c9:35:43:f5
3 3 cu AN No_Sync
4 4 cu AN No_Sync Disabled (Persistent)
5 5 cu N4 Online F-Port 50:06:0b:00:00:3c:b4:3e
6 6 cu N4 Online F-Port 10:00:00:00:c9:35:43:f3
7 7 cu AN No_Sync Disabled (Persistent)
8 8 cu AN No_Sync
9 9 cu AN No_Sync Disabled (Persistent)
10 10 cu AN No_Sync Disabled (Persistent)
11 11 cu AN No_Sync Disabled (Persistent)
12 12 cu AN No_Sync Disabled (Persistent)
13 13 cu AN No_Sync Disabled (Persistent)
14 14 cu AN No_Sync Disabled (Persistent)
15 15 cu AN No_Sync Disabled (Persistent)
16 16 cu AN No_Sync Disabled (Persistent)
17 17 -- N4 No_Module
18 18 -- N4 No_Module
19 19 -- N4 No_Module
20 20 -- N4 No_Module
21 21 id N4 Online E-Port segmented,(zone conflict)(Trunk master)
22 22 id N4 Online E-Port (Trunk port, master is Port 21 )
23 23 id N4 Online E-Port (Trunk port, master is Port 21 )
switch:admin> switchdisable
Note
To save the switch configuration, use the configUpload command before proceeding
with the next step.
switch:admin> ag --modeenable