Brocade Access Gateway Administrator's Guide - Supporting Fabric OS v5.2.1 (53-1000430-01)

D-6 Access Gateway Administrator’s Guide
Publication Number: 53-1000430-01
AG-1004
D
Severity WA RN I NG
AG-1004
Message
Probable
Cause
Indicates that fabric sent an invalid response to FLOGI ELS of the specified N_Port.
Recommended
Action
Verify the fabric switch's configuration.
If the message persists, run supportFtp to set up automatic FTP transfers; then run the supportSave
command and contact your switch service provider.
Severity ERROR
AG-1005
Message
Probable
Cause
Indicates that the F_Port which connects to the host is offline.
Recommended
Action
Verify the configuration of the host connected to the specified F_Port.
Severity WA RN I NG
AG-1006
Message
Probable
Cause
Indicates that the F_Port which connects to the host did not send FLOGI request for
10 times E_D_TOV. F_Port is disabled.
Recommended
Action
Verify the HBA driver configuration of the host connected to the specified F_Port. Access Gateway
supports Fabric mode connectivity only.
<timestamp>, [AG-1004], <sequence-number>,, ERROR, <system-name>,
Invalid response to fabric login (FLOGI) request from the fabric for
N_Port <port>.
<timestamp>, [AG-1005], <sequence-number>,, WARNING, <system-name>,
FDISC response dropped because F_Port <port> is offline.
<timestamp>, [AG-1006], <sequence-number>,, WARNING, <system-name>,
FLOGI request was not received from F_Port <port>. Port is being
disabled