Brocade Access Gateway Administrator's Guide - Supporting Fabric OS v5.2.1 (53-1000430-01)

Access Gateway Administrator’s Guide D-7
Publication Number: 53-1000430-01
AG-1007
D
Check GBIC and other connecting cables and re-enable the F_Port using the portEnable command.
Severity WA RN I NG
AG-1007
Message
Probable
Cause
Indicates the N_Port which is connected to the fabric switch is not online. The N_Port has been
disabled.
Recommended
Action
Check the connectivity between Access Gateway N_Port and fabric switch port.
Severity WA RN I NG
AG-1008
Message
Probable
Cause
Indicates that the fabric switch management server did not accept the login (PLOGI) request sent by the
Access Gateway from the specified N_Port.
Recommended
Action
Verify the configuration on the fabric switch that is connected to the Access Gateway.
If the message persists, run supportFtp to set up automatic FTP transfers; then run the supportSave
command and contact your switch service provider.
Severity WA RN I NG
AG-1009
Message
Probable
Cause
Indicates that the fabric login (FLOGI) request sent to the fabric switch from the Access Gateway
failed.
Recommended
Action
Verify the configuration of the fabric switch..
<timestamp>, [AG-1007], <sequence-number>,, WARNING, <system-name>,
FLOGI response not received for the N_Port <port> connected to
fabric
<timestamp>, [AG-1008], <sequence-number>,, WARNING, <system-name>,
Invalid PLOGI response from the fabric on the N_Port <port>
<timestamp>, [AG-1009], <sequence-number>,, WARNING, <system-name>,
FLOGI sent from N-Port <port> failed