Brocade Fabric OS Command Reference Manual - Supporting Fabric OS v5.3.0 (53-1000436-01, June 2007)

Fabric OS Command Reference Manual 285
53-1000436-01
historyLastShow
2
historyLastShow
Displays the latest entry in the field replaceable unit (FRU) history log.
Synopsis historylastshow
Description Use this command to display the contents of the latest history log, which records insertion and
removal events for blades, power supplies, fans, and World Wide Cards. A history record contains
three lines of information. The first line of each record contains the following data sets:
Object type FAN, POWER SUPPLY, and one CP switches.
Object number Slot number for blades and unit number for everything else.
Event Inserted, Removed, or Invalid.
Time of the event Format: Day Mon dd hh:mm:ss yyyy
The second and third lines of a record each contain one data set, preceded by its name:
Factory Part Number xx-yyyyyyy-zz or Unknown
Factory Serial Number
xxxxxxxxxxxx or Unknown
The execution of this command is subject to Admin Domain restrictions that may be in place.
Operands none
Examples To display the late FRU insertion or removal event:
switch:admin> historylastshow
POWER SUPPLY Unit 2 Inserted at Tue Aug 14 15:52:10 2001
Factory Part Number: 60-0001536-02
Factory Serial Number: 1013456800
Records: 11
See Also historyShow