Brocade Fabric OS Command Reference Manual - Supporting Fabric OS v5.3.0 (53-1000436-01, June 2007)

Fabric OS Command Reference Manual 549
53-1000436-01
psShow
2
psShow
Displays power supply status.
Synopsis psshow
Description Use this command to display the current status of the switch power supplies.
The status of each supply is displayed as:
OK Power supply functioning correctly.
absentPower supply not present.
unknownUnknown power supply unit installed.
predicting failurePower supply is present but predicting failure.
faultyPower supply present but faulty (no power cable, power switch turned off, fuse blown, or other
internal error).
For certain switch models, the OEM serial ID data displays after each power supply status line.
The execution of this command is subject to Admin Domain restrictions that may be in place.
Operands none
Examples To view the status of the power supplies:
switch:admin> psshow
Power Supply #1 is OK
DELTA DPS-1001AB-1E 23000000601 S1 IXD0111000088
Power Supply #2 is faulty
DELTA DPS-1001AB-1E 23000000601 S1 IXD0111000162
Power Supply #3 is OK
DELTA DPS-1001AB-1E 23000000601 S1 IXD0111000120
Power Supply #4 is absent
See Also chassisShow, fanShow