fcFxPortPhysTable 1.3.6.1.3.42.2.1.2.3
3
fcFxPortPhysTable 1.3.6.1.3.42.2.1.2.3
A table that contains, one entry for each Fx_Port in the fabric element, physical level status and
parameters of the Fx_Ports.
fcFxPortPhysEntry 1.3.6.1.3.42.2.1.2.3.1
An entry containing physical level status and parameters of an Fx_Port.
Index fcFxPortPhysModuleIndex, fcFxPortPhysFxPortIndex
fcFxPortPhysModuleIndex 1.3.6.1.3.42.2.1.2.3.1.1
Identifies the module containing the Fx_Port for which this entry contains information.
fcFxPortPhysFxPortIndex 1.3.6.1.3.42.2.1.2.3.1.2
Identifies the Fx_Port within the module. This number ranges from 1 to the value of
fcFeModulePortCapacity for the associated module. The value remains constant for the identified
Fx_Port until the module is reinitialized.
fcFxPortPhysAdminStatus 1.3.6.1.3.42.2.1.2.3.1.3
The desired state of the Fx_Port:
online (1) Place port online
offline (2) Take port offline
testing (3) Initiate test procedures
A management station might place the Fx_Port in a desired state by setting this object accordingly. The
testing state (3) indicates that no operational frames can be passed. When a fabric element initializes, all
Fx_Ports start with fcFxPortPhysAdminStatus in the offline state (2). As the result of either explicit
management action or per configuration information accessible by the fabric element,
fcFxPortPhysAdminStatus is then changed to either the online (1) or testing (3) states or remains in the
offline state (2).
fcFxPortPhysOperStatus 1.3.6.1.3.42.2.1.2.3.1.4
The current operational status of the Fx_Port:
online (1) Login might proceed.
offline (2) Login cannot proceed.
testing (3) Port is under test.
link-failure (4) Failure after online/testing.