Brocade Fabric OS MIB Reference (53-1000241-01, November 2006)

5-14 Fabric OS MIB Reference
Publication Number: 53-1000241-01
swSensorScn 1.3.6.1.4.1.1588.2.1.1.1.0.2
5
Enterprise sw
Variables “swDiagResult 1.3.6.1.4.1.1588.2.1.1.1.1.20”
“swSsn 1.3.6.1.4.1.1588.2.1.1.1.1.10
A swFault is generated whenever the diagnostics detect a fault with the switch.
swSensorScn 1.3.6.1.4.1.1588.2.1.1.1.0.2
(Obsoleted by swFabricWatchTrap)
Enterprise sw
Variables “swSensorStatus 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3”
“swSensorIndex 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.1”
“swSensorType 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2”
“swSensorValue 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4”
“swSensorInfo 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5”
“swSsn 1.3.6.1.4.1.1588.2.1.1.1.1.10
A swSensorScn (2) is generated whenever an environment sensor changes its operational state: for
instance, if a fan stop working. The VarBind in the Trap Data Unit contain the corresponding instance of
the sensor status, sensor index, sensor type, sensor value (reading), and sensor information. Note that
the sensor information contains the type of sensor and its number, in textual format.
swFCPortScn 1.3.6.1.4.1.1588.2.1.1.1.0.3
Enterprise sw
#TYPE Switch is faulty.
#SUMMARY Faulty reason: %d and SSN is #%s
#ARGUMENTS 0, 1
#SEVERITY Critical
#TIMEINDEX 1
#STATE Nonoperational
#TYPE A sensor (temperature, fan, or other) changed its
operational state.
#SUMMARY %s: is currently in state %d and SSN is #%s
#ARGUMENTS 4, 0, 5
#SEVERITY Informational
#TIMEINDEX 1
#STATE Operational