Brocade Fabric OS MIB Reference (53-1000241-01, November 2006)

Fabric OS MIB Reference 5-15
Publication Number: 53-1000241-01
swEventTrap 1.3.6.1.4.1.1588.2.1.1.1.0.4
5
Variables “swFCPortOpStatus 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.4”
“swFCPortIndex 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.1”
“swFCPortName 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.36”
“swSsn 1.3.6.1.4.1.1588.2.1.1.1.1.10
A swFCPortScn (3) is generated whenever an FC_Port changes its operational state: for instance, the
FC_Port goes from online to offline. The VarBind in the Trap Data Unit contain the corresponding
instance of the FC_Port's operational status, index, swFCPortName, and swSsn. swFCPortName and
swSsn are optional.
Sample trap output for Fabric OS 4.4.0:
swFCPortOpStatus.11 = offline(2)
swFCPortIndex.11 = 11
swFCPortName.11 = test
swSsn.0 = none
swEventTrap 1.3.6.1.4.1.1588.2.1.1.1.0.4
Enterprise sw
Variables “swEventIndex 1.3.6.1.4.1.1588.2.1.1.1.8.5.1.1
“swEventTimeInfo 1.3.6.1.4.1.1588.2.1.1.1.8.5.1.2”
“swEventLevel 1.3.6.1.4.1.1588.2.1.1.1.8.5.1.3
“swEventRepeatCount 1.3.6.1.4.1.1588.2.1.1.1.8.5.1.4”
“swEventDescr 1.3.6.1.4.1.1588.2.1.1.1.8.5.1.5”
“swSsn 1.3.6.1.4.1.1588.2.1.1.1.1.10
This trap is generated when an event occurs with a level that is at or below “swEventTrapLevel
1.3.6.1.4.1.1588.2.1.1.1.8.1”.
#TYPE A Fibre Channel Port changed its operational state.
#SUMMARY Port Index %d changed state to %d. Port Name: %s and
SSN is #%s
#ARGUMENTS 1, 0, 2, 3
#SEVERITY Informational
#TIMEINDEX 1
#STATE Operational
#TYPE A firmware event has been logged.
#SUMMARY Event %d: %s (severity level %d) - %s SSN is #%s