Brocade Fabric OS MIB Reference (53-1000241-01, November 2006)

Fabric OS MIB Reference 5-33
Publication Number: 53-1000241-01
swFCPortPhyState 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.3
5
swFCPortPhyState 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.3
The physical state of the port.
Values Possible values are:
noCard (1) No card is present in this switch slot.
noTransceiver (2) No Transceiver module in this port (Transceiver is the generic name for GBIC,
SFP, and so on).
laserFault (3) The module is signaling a laser fault (defective GBIC).
noLight (4) The module is not receiving light.
noSync (5) The module is receiving light but is out of sync.
inSync (6) The module is receiving light and is in sync.
portFault (7) The port is marked faulty (defective GBIC, cable, or device).
diagFault (8) The port failed diagnostics (defective G_Port or FL_Port card or motherboard).
lockRef (9) Port is locking to the reference signal.
swFCPortOpStatus 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.4
The operational status of the port.
Values Possible values are:
unknown (0) The port module is physically absent.
online (1) User frames can be passed.
offline (2) No user frames can be passed.
testing (3) No user frames can be passed.
faulty (4) The port module is physically faulty.
swFCPortAdmStatus 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.5
The desired state of the port. A management station might place the port in a desired state by setting this
object accordingly.
Values Possible values are:
online (1) User frames can be passed.
offline (2) No user frames can be passed.
testing (3) No user frames can be passed.
faulty (4) No user frames can be passed.
For Fabric OS v3.x:
The 3 (testing) state indicates that no user frames can be passed. As the result of either explicit
management action or per configuration information accessible by the switch, swFCPortAdmStatus is
then changed to either the 1 (online) or 3 (testing) states or remains in the 2 (offline) state.
For Fabric OS v4.x:
The 3 (testing) state is not supported.