Brocade Fabric OS MIB Reference (53-1000241-01, November 2006)

Fabric OS MIB Reference 8-47
Publication Number: 53-1000241-01
connUnitSensorStatusChange
8
Recommended severity level (for filtering): info.
Sample trap output for Fabric OS v4.4.0:
connUnitEventId.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.354 = 354
connUnitEventType.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.354 = other(2)
connUnitEventObject.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.354 = null
connUnitEventDescr.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.354 = FW-1425 Switch
status changed from MARGINAL to HEALTHY.
See the swEventTrap for more details.
connUnitSensorStatusChange
Enterprise fcmgmt
Variables connUnitSensorStatus
Overall status of the connectivity unit has changed.
This trap is generated whenever the status of the sensors (like fan, power supply, temperature) present in
the connectivity unit changes.
Sample trap output for Fabric OS v4.4.0:
connUnitSensorStatus.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.7 = failed(5)
See the Fabric Watch Administrator’s Guide for information on configuring thresholds that generate
these traps.
connUnitPortStatusChange
Enterprise fcmgmt
Variables connUnitPortStatus, connUnitPortState
Overall status of the connectivity unit changed. Recommended severity level (for filtering): alert.
This trap sends the instance of connUnitPortName as part of the trap; the instance string is NULL, if the
port name is not defined for the specified port.
Sample trap output for Fabric OS v4.4.0:
connUnitPortStatus.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.29 = ready(3)
connUnitPortState.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.29 = online(2)
connUnitPortName.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.29 = test
See the swFCportSCN for more information.