Brocade Fabric OS MIB Reference Supporting Fabric OS v7.0.0 (53-1002151-01, April 2011)

144 Fabric OS MIB Reference
53-1002151-01
Switch system group
6
swBrcdTrapBitMask
1.3.6.1.4.1.1588.2.1.1.1.1.34
Not
accessible
This represents the type of notification by a single bit.
0x01 - Fabric change event
0x02 - Device change event
0x04 - FAPWWN change event
0x08 - FDMI events
swFCPortPrevType
1.3.6.1.4.1.1588.2.1.1.1.1.35
Not
accessible
This represents the port type of a port before it goes online or
offline and it is valid only in swFcPortSCN trap.
Valid values are:
unknown (1)
other (2)
fl-port (3) - public loop
f-port (4) - fabric port
e-port (5) - fabric expansion port
g-port (6) - generic fabric port
ex-port (7)
TABLE 16 Sensors on the various Brocade switches
Platform Temp Fans Power supply swNumSensors /
connUnitNumSensors
Brocade 200E 2 sensors 3 fans 1 PS 6
Brocade 300 3 sensors 3 fans 1 PS 7
Brocade 3014 3 sensors NA NA 3
Brocade 3016 4 sensors NA NA 4
Brocade 3250 4 sensors 3 fans 1 PS 8
Brocade 3850 4 sensors 4 fans 2 PS 10
Brocade 3900 5 sensors 6 fans 2 PS 13
Brocade 4012 2 sensors NA NA 2
Brocade 4016 3 sensor NA NA 3
Brocade 4018 1 sensor NA NA 1
Brocade 4020 2 sensors NA NA 2
Brocade 4024 2 sensors NA NA 2
Brocade 4100 5 sensors 3 fans 2 PS 10
Brocade 4424 3 sensors NA NA 3
Brocade 4900 3 sensors 3 fans 2 PS 18
Brocade 5000 4 sensors 2 fans 2 PS 8
Brocade 5100 4 sensors 2 fans 2 PS 8
Brocade 5300 3 sensors 3 fans 2 PS 8
Brocade 5410 3 sensors NA NA 3
Brocade 5424 3 sensors NA NA 3
Brocade 5450 2 sensors NA NA 2
Brocade 5460 2 sensors NA NA 2
Object and OID Access Description