Brocade Fabric OS MIB Reference Supporting Fabric OS v7.0.0 (53-1002151-01, April 2011)

Fabric OS MIB Reference 151
53-1002151-01
Fibre Channel port group
6
swFCPortPhyState
1.3.6.1.4.1.1588.2.1.1.1.6.2
.1.3
Read only The physical state of the port.
Possible values are:
noCard (1) - No card is present in this switch slot.
noTransceiver (2) - No Transceiver module in this port
(Transceiver is the generic name for GBIC, SFP, and so on).
laserFault (3) - The module is signaling a laser fault (defective
GBIC).
noLight (4) - The module is not receiving light.
noSync (5) - The module is receiving light but is out of sync.
inSync (6) - The module is receiving light and is in sync.
portFault (7) - The port is marked faulty (defective GBIC, cable, or
device).
diagFault (8) - The port failed diagnostics (defective G_Port or
FL_Port card or motherboard).
lockRef (9) - The port is locking to the reference signal.
validating (10) - The module is being validated.
invalidModule (11) - The module is invalid.
unknown (255) - The module is unknown.
swFCPortOpStatus
1.3.6.1.4.1.1588.2.1.1.1.6.2
.1.4
Read only The operational status of the port.
Possible values are:
unknown (0) - The port module is physically absent.
online (1) - User frames can be passed.
offline (2) - No user frames can be passed.
testing (3) - No user frames can be passed.
faulty (4) - The port module is physically faulty.
swFCPortAdmStatus
1.3.6.1.4.1.1588.2.1.1.1.6.2
.1.5
Read-write The desired state of the port. A management station might place the
port in a desired state by setting this object accordingly.
Based on the port status, this OID returns one of the following:
Online - When queried port is online.
Offline - When queried port is offline.
Faulty - When port is in faulty state.
The following values can be used to set this object:
Online - To change port's state to Online.
Offline - To change port's state to Offline.
swFCPortLinkState
1.3.6.1.4.1.1588.2.1.1.1.6.2
.1.6
Read-write Indicates the link state of the port. When the port's link state changes,
its operational status (swFCPortOpStatus) is affected.
Possible values are:
enabled (1) - The port is allowed to participate in the FC-PH
protocol with its attached port (or ports if it is in an FC-AL loop).
disabled (2) - The port is not allowed to participate in the FC-PH
protocol with its attached ports.
loopback (3) - The port might transmit frames through an internal
path to verify the health of the transmitter and receiver path.
swFCPortTxType
1.3.6.1.4.1.1588.2.1.1.1.6.2
.1.7
Read only Indicates the media transmitter type of the port.
Possible values are:
unknown (1) - Cannot determine the port driver.
lw (2) - Long wave laser.
sw (3) - Short wave laser.
ld (4) - Long wave LED.
cu (5) - Copper (electrical).
Object and OID Access Description