Brocade Fabric OS MIB Reference Supporting Fabric OS v7.0.0 (53-1002151-01, April 2011)

Fabric OS MIB Reference 217
53-1002151-01
Connectivity unit group
9
connUnitEventSeverity
1.3.6.1.3.94.1.11.1.6
Read only The event severity level. The mapping between error log severity level
and this variable is:
Error log FA-MIB
none (0) unknown (1)
Critical (1) critical (4)
Error (2) error (5)
Warning (3) warning (6)
Informational (4) info (8)
Debug (5) debug (9)
For more information about severity, refer to “FcEventSeverity” in Table
22 on page 199.
connUnitEventType
1.3.6.1.3.94.1.11.1.7
Read only The type of this event.
Possible values are:
unknown (1)
other (2)
status (3)
configuration (4)
topology (5)
Always set to 2 (other).
connUnitEventObject
1.3.6.1.3.94.1.11.1.8
Read only This is used with the connUnitEventType to identify to which object the
event refers. It can be the OID of a connectivity unit or of another object,
like connUnitPortStatus.
Always set to null.
connUnitEventDescr
1.3.6.1.3.94.1.11.1.9
Read only The description of the event.
Same as the string displayed in the system error log. The system error
log can be viewed using the errShow or errDump commands.
For Fabric OS v6.2.0 and later releases, the format of error messages
has changed. This field now uses the message title and number (for
example, WEBD-1006) and the message text. Previously, this field used
the task ID and all the message number and message text. For more
information on error messages, refer to Fabric OS Message Reference.
Object and OID Access Description