Defect ID: DEFECT000312579
Technical Severity: Medium
Summary: zoned panic during hafailover during firmwaredownload on Brocade 48000 in IM2 mode
Symptom: When upgrading from Fabric OS v6.3.x to v6.4.x, the switch experienced a panic on zoned
after the initial failover with the new CP at v6.4.x with a cold recovery of the switch. This
only impacts Brocade 48000 running IM2 mode.
Feature: Field Escalation
Function: Panic / OOM
Probability: High
Found in Release: FOS6.4.0
Service Request ID: 445873
Where Else Fixed: FOS6.4.1 a
Defect ID: DEFECT000314056
Technical Severity: Medium
Summary: Due to incorrect internal counter logic, PORT-1003 port faults are being reported in the
RASLOG when they shouldn't be.
Symptom: After a long switch uptime, if there are greater than 50 link down events before a switch is
rebooted (as opposed to within 2 minutes), the port is faulted with a PORT-1003 being
reported in the RASLOG.
Feature: Diagnostics
Function: Other
Probability: Low
Found in Release: FOS5.3.0
Service Request ID: 443043
Where Else Fixed: FOS6.2.2 d, FOS6.4.1 a
Defect ID: DEFECT000314717
Technical Severity: Medium
Summary: Fabric Watch reports TX/RX Performance over 100%.
Symptom: Shortly after executing the statsclear command, fabric watch reports a TX/RX performance
over 100%.
Workaround: Use the slotstatsclear command instead of the statsclear command.
Feature: 8G Platform Services
Function: Other
Probability: Low
Found in Release: FOS6.4.0
Service Request ID: 447457
Where Else Fixed: FOS6.3.2 b, FOS6.4.1 a
Defect ID: DEFECT000315478
Technical Severity: Medium
Summary: After enabling SCC policy on edge switch, F_Ports get disabled
Symptom: After configuring the SCC Policy only on edge switch, then removing the front domains of
the FCR from the SCC followed by disabling/enabling of the edge switch, the F_Ports get
disabled with the following message: 2010/08/20-16:19:45, [SEC-1187], 1433, FID 128,
INFO, T5300_161, Security violation: Unauthorized switch 20:00:00:05:1e:0a:54:ca tries
to join fabric.
Feature: FC Services
Function: Fabric
Probability: High
Found in Release: FOS6.4.1_fcoe
Where Else Fixed: FOS6.4.1 a