Brocade Fabric OS v6.4.3f Release Notes v1.0

Fabric OS v6.4.3f Release Notes v1.0 Page 45 of 149
Closed with Code Change in Fabric OS v6.4.3d
This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of
March 20, 2013 in Fabric OS v6.4.3d.
Defect ID:
DEFECT000422477
Technical Severity:
High
Summary:
HBA on embedded switch port does not login correctly after the host is rebooted or unstable
ICL/other ports can cause switch reboot
Symptom:
Embedded switch port must be disabled/enabled once the host is fully booted to support successful
HBA login. This defect also has implication on DCX, FX8-24 etc., with unstable ICL/BI ports, it can
cause switch to panic.
Probability:
Medium
Feature:
FOS Software
Function:
ASIC Driver
Reported In Release:
FOS7.0.2
Service Request ID:
1032557
Defect ID:
DEFECT000431588
Technical Severity:
Medium
Summary:
FC8-64 in Slot 1 of DCX+ Faulting During Serdes Auto Tuning. The change also applies to DCX.
Symptom:
FC8-64 running in slot 1 of a DCX+ experienced blade fault due to excessive CRC w/good EOF
errors. Autotuning was attempted but blade fault occurred before an alternate value could be derived
to resolve the errors.
Probability:
Low
Feature:
8G ASIC Driver
Function:
C2 ASIC driver
Reported In Release:
FOS7.0.2
Service Request ID:
1087861