HP StorageWorks Fabric OS 5.2.1b Release Notes (AA-RWEYC-TE, June 2007)

portcfgdefault
command function change
for the Brocade 4Gb S AN
Switch for HP c-Class
BladeSystem
With Fabric OS 5.2.1b, the portcfgdefault command now resets the
conguration to HP factory default port settings.
Update to Brocade 4Gb
SAN Switch for HP c-Class
BladeSystem instructions.
After connecting to the Brocade 4Gb SAN Switch via the Onboard
Administrator (OA) connect command, you will be in the swi tch CLI prompt.
To return to the OA serial prompt:
Type Exit to log out of the switch.
Press Shift-Ctrl-underscore (escape sequence) to return to the OA prompt.
Zoning considerations with
FC4–48 blade
B-Series switches running pre-5.2.0 rmwaredonotacceptzonedatabases
with Domain, Port Index, references to ports higher than 255. Zoning in Fabric
OS 5.2.0 and later, therefore, do not allow a Domain, Port Index entry for
ports above 255 to be created unless all switches in the fabric are at
Zoning considerations continued...
Fabric OS 5.2.0 or later versions. Once such an entry has been put into
the zone database, an attempt to connect a pre-Fabric OS 5.2.0 switch to
thefabricresultsinthatswitchbeingsegmentedwithaZoneMismatch
segmentation reason.
Anyzoningthatisalreadyinusecancontinuetobeused. However,in
Fabrics containing pre-Fabric OS 5.2.0 switches, if new devices are added
on the upper 16 ports (ports 32-47) of the FC4-48 port blade, then WWN
zoning has to be used for those devices. I f there is an existing Domain Port
Index zone that connects to p orts 32–47, HP recommends that you transform
just that zone to WWN zoning. This would minimize the likelihood of
rebuilding the entire fabric.
Fabrics containing only Fabric OS 5.2.0 and later switches have no zoning
limitation.
Fabric OS 5.2 .1 xes
Table
3 lists defects closed in the Fabric OS 5.2.1 rmware release.
Table 3 Fabric OS 5.2.1 c losed defects
Closed defect summary
Solution
4/256 director running FICON with fsmode enabled panics after
upgradefromFOSv5.0.x,toeitherv5.1.xorv5.2.0.
Fixed per Fabric OS 5.2.1.
After previous diag failure, 2/128 director LEDs may blink indicating
afail
ure on subsequent diag command execution, even though
slot
show command shows proper operation.
Fixed per Fabric OS 5.2.1.
FR4-18i router blade POST failed after slotpoweroff/on.
Fixed per Fabric OS 5.2.1.
Error messages may result after a lot of diagnostic tests run during
warm recovery on standby .
Fixed per Fabric OS 5.2.1.
Swit
ch panics in rare cases during HAfailover due to zoning daemon
asse
rtion.
Fixed per Fabric OS 5.2.1.
Panic observed on new active CP after HAfailover, running I/O
through AD, mirrored por t and FC4-48.
Unlikely user scenario
Fixed per Fabric OS 5.2.1.
Fastboot on remote switch followed by H Afailover on 4/256 can
cause mu ltiple kernel panics & error messages.
Unlikely user scenario
Fixed per Fabric OS 5.2.1.
Whe
n using continuous mode in Fabric Watch with timing interval of
1se
cond, too many e-mail alert messages can cause unexpected
termination of other processes.
Fix
ed per Fabric OS 5.2.1.
HP StorageWorks Fabric OS 5.2.1b release notes