HP StorageWorks Fabric OS 5.3.0d Release Notes (AA-RWEYH-TE, December 2007)

Topic Description
FC Routing
If an HP StorageWorks MP Router is present in the backbone fabric, the
command fcrDisable may take up to 8 minutes to complete. If the
MP Router is replaced by a B-Series MP Router Blade (FR4-18i) or an HP
StorageWorks 400 MP Router, the command completes immediately.
EX_Port trunking is not enab led by default.
FCR switch does not support an edge fabric with one McDATA switch set to
never principal’. The EX_Port connected to that edge fabric will not come up.
FCR switch does not support edge fabrics that consist of McDATA switches
with domain ID offset’. The EX_Port connected to that edge fabric may fail
the RDI process and will not come up. EX_Ports come up disabled (failed to
init in time) if attached to a Native mode switch running EOS 9.x that has
non-default DID offset congured.
Device discovery may fail when an HBA uses the GA_NXT name server query
to discover devices through an FCR switch since the query is mishandled
by the FCR.
Secur ity
Remove any password enforced expiration of admin or root accounts b efore
downgrading rmware to 5.0.1 or earlier versions.
Diagnostics
All ofine diagnostics commands should b e used only when the switch is
disabled.
Installing new SFPs during POST may cause POST to fail. Install SFPs only
when the switch is online or if the switch is powered off.
When you use the diagnostic commands systemVerification and
diagSetBurnin, the switch or Blade faults when the burn-in error log
is full. Clear the burn-in log before running systemVerification or
diagSetBurnin.
IfthereISLsresideontheswitchthatarenotusedforroutingbecausethey
have higher link costs, disable the links before running spinfab.
HA
If there is an already segmented port and backbone devices are exported to
an edge fabric, a build fabric/fabric reconguration can occur after running
haFailover. E nsure that there no segmented port exist before upgrading
rmware.
IPSec for B-Series MP
Router Blade (FR4–18i)
IPSec implementation details:
Pre-shared key
Main mode (IKE negotiation protocol)
Tunn el mode in Encapsulating Security Payload (ESP)
IPSec specic statistics not provided.
No NAT or IPV6 support
FastWrite and Tape Pipelining will not be supported in conjunction with secure
tunnels.
Jumbo frames will not be supported on secure tunnels.
ICMP redirect is not supported for IPSec-enabled tunnels.
Only a single secure tunnel will be allowed on a por t. Non-secure tunnels will
not be allowed on the same port as secure tunnels.
Modify operations are not allowed on secure tunnels. To change the
conguration of a secure tunnel, you must rst delete the tunnel and then
re-create it with the desired options.
Onlyasinglerouteissupportedonaninterfacewithasecuretunnel.
An IPSec tunnel cannot be created using the same local IP address if ipperf is
active and using the same local IP address (source IP address).
Unidirectional supported throughput is ~104Mbytes/sec and bidirectional
supported throughput is ~ 90Mbytes/sec.
An IPSec tunnel takes longer to come online than a non-IPSec tunnel.
Fabric Merge
Do not try to merge fabrics with conicting domain IDs over a VE_P ort. Before
merging two fabrics over FC-IP with VE_Ports at each end, HP recommends that
all domain ID and zoning conicts be resolved.
HP StorageWorks Fabric OS 5.3.0d release notes
13