HP StorageWorks Auto Path for AIX, v04.02 - Installation Guide (B7949-96005)

19HP StorageWorks Auto Path for AIX: Installation Guide
Installation
9. Verify that the package was installed.
# lslpp -L AutoPath.rte
Verify that AutoPath.rte appears among the file set items in the output list
and that its status is C (Commit). See the readme file on the Auto Path for
AIX CD for the current level.
10. Verify that the dlmfdrv.conf or dlmfdrv.unconf file is in the
/usr/DynamicLinkManager/drv directory.
11. Activate the DLM subsystem.
# dlmcfgmgr
A system reboot also activates the DLM subsystem.
The dlmfdrv device files are regenerated as configured in the dlmfdrv.conf or
dlmfdrv.unconf file.
12. Activate all of the DLM volume groups.
Example # dlmvaryonvg dlmvg01
13. Make the mount point available.
Example # mount /tmp/dlmvg01_fs