HP StorageWorks Replication Solutions Manager Command Line User Interface Reference (T3687-96029, August 2005)

[[diskg[roup]dg=<diskgroup name>]
|[redundancy_level|rl={same|raid0|raid1|raid5}]]
Description
Use the ADD SNAPCLONE command to create a local replica of the specied virtual disk.
Switches
snapclone name Species the name of the snapclone.
vdisk Species the n am e of the source virtual disk.
nowait Creates the snapclone without waiting for normalization to complete.
wait Waits for the snapclone to normalize before returning to the p rompt.
This is the default. For large cloning operations, this may take some
time to complete.
diskgroup Species the disk group for this snapclone to be created in.
redundancy_level Species the redundancy (Vraid) level of the snapclone copy. Valid
values are SAME, RAID0, RAID1,orRAID5.ThedefaultisSAME.
See Cross Vraid rules in the HP Replication Solutions Manager
online help and user guide for information on redundancy levels.
ADD SNAPSH
OT
Synopsis
a[dd] snaps[hot]|ss <snapshot name>
{vd[isk]={vdisk name}}
[nowait]
[wait]
[[redundancy_level|rl={same|raid0|raid1|raid5}]
|[snapshot_type|st={demand_allocated|da|fully_allocated|fa}]]
Descript
ion
Use the ADD SNAPSHOT command to create a local replica of the specied virtual disk.
Switches
snapshot name Species the name of the snapshot.
nowait Creates the snapshot without waiting for normalization to c omplete.
wait Waits for the sna pshot to normalize before returning to the prompt.
This is the default.
redundancy level Species the snapshot redundancy level. Valid values are SAME,
RAID0, RAID1,orRAID5.ThedefaultisSAME.See Cross Vraid rules
in the HP Replication Solutions Manager online help and user guide
for information on redundancy levels.
snapshot_type Species the snapshot t ype. Valid values are demand_allocated or
fully_allocated.Thedefaultisdemand_allocated.
24
CLUI commands