HP StorageWorks External Storage XP user guide for the XP12000, XP10000, SVS200 (T1706-96009, October 2007)

Local array ports. After selecting a port, you can add paths. One of the following icons appears for
each port:
Port in Standard mode.
Port in Initiator/External MIX mode.
Selected Paths
Paths that are added as ports that congure alternate paths. WWNs identify ports on the external
array. Nothing is displayed when you initially access the Add Paths window.
Unselected Paths
External array ports (WWNs) that can congure the path connecting with the local array port selected
in the Port list. Select WWNs from this list to add as alternate paths.
Set
Moves WWNs selected in Unselected Paths to Selected Paths.
Release
Moves WWNs selected in Selected Paths to Unselected Paths.
OK
Saves settings in the Add Paths window, closes the Add Paths window, and displays the Path Setting
window.
Cancel
Cancels all settings in the Add Paths window, and closes the window.
To add alternate paths to multiple external LUs at one time:
1. Select the LU Operation tab. The LU Operation pane appears.
2. In the Device tree, select an external LU group number. Information about external LUs mapped
as internal LDEVs appears in the Device list.
3. In the Device list, select multiple external LUs, right-click, and select Add Paths. The Add Paths
window appears.
4. In the Port list, select the local array port. External array ports (WWNs) that can congure the path
connecting with the selected local array port appear in Unselected Paths.
5. In the Unselected Paths list, select the port's WWNs, and click Set. The selected WWNs move to
Selected Paths.
6. Click OK. The Path Setting window appears.
7. Ensure that added paths are applied to the array in the Path Setting window. You can also change
the alternate path setting in this window. For more information, see Setting alternate paths for
external LUs.
8. Click OK. The Path Setting window closes, and the LU Operation pane appears.
Selected rows in the Device list appear in blue italics. Specied settings appear in the Preset list. To
check setting details, right-click the setting in the Preset list, and select Detail. To cancel settings,
right-click the setting in the Preset list, and select Delete
.
9. Click Apply.Aconrmation message appears.
10. Click OK. Alternative paths added using the Add Paths and Path Setting windows are applied to
the array, and the specied content appears in the Device list.
If errors occur during alternate path denition, failed settings and error codes appear in the Preset
list. To check error messages, right-click the failed setting, and select Detail.
External Storage XP user guide
103