HP StorageWorks External Storage XP user guide for the XP12000, XP10000, SVS200 (T1706-96009, October 2007)

Icon
Description
Port in Standard mode.
Port in Initiator/External MIX mode.
Port list
Displays infor
mation about the ports and paths of the local array or external array, depending on the
item selected in the Port tree. You can sort the list by displayed items. For instance, to sort the items by
the port number, select Port on the list.
Figure 34 Port list (External selected in Port tree)
The display
ed contents changes depending on the item selected in the Port tree.
Subsystem
When selected, displays nothing in the Port tree. Subsystem is selected when you initially display
the Port tr
ee.
External
Port:PortofthelocalarraywiththeportattributeissettoExternal. One of the following
icons appears for each port:
Icon
Description
Port in Standard mode.
Port in Initiator/External MIX mode.
Path: Number of set paths.
FLI_TOV
: Wait time (in seconds) from the switch to FLOGI when the switch is connected.
External Storage XP automatically sets this value. You cannot change the value.
PLI_TOV: Wait time (in seconds) of PLOGI to the external array when the switch is not
connec
ted. External Storage XP automatically sets this value. You cannot change the value.
Margin: Additional wait time (in seconds) to FLI_TOV (FLOGI wait time) or PLI_TOV (PLOGI
wait time). External Storage XP automatically sets this value. You cannot change the value.
As a result, the sum of the FLI_TOV time and margin time, or the sum of the PLI_TOV time
and ma
rgin time is set as a total wait time.
Status: Status of the path set in the port identied by the WWN. The highest emergency level
status is displayed when two or more paths are set. One of the following statuses is displayed:
Normal:Pathisnormal.
Unkn
own: Path status is unknown.
Blockade:Pathisblocked.
70
External Storage XP panes