3.6.0 Matrix Server Installation Guide (5697-7079, February 2008)

Chapter 3: Install PolyServe Matrix Server 26
Copyright © 1999-2008 PolyServe, Inc. All rights reserved.
first FC switch. Repeat this procedure to specify the remaining FC
switches, including cascading switches. If you are using an MPIO
configuration, be sure to configure all of the switches.
2. SNMP Community String. The default SNMP community string for
Matrix Server is private. If you want to use a custom community
string, enter the appropriate value here. The SNMP community string
must be set to the same value on Matrix Server and on the SAN
switches configured above.
When you have completed the information, go to the
Storage Settings tab.
Web Management-Based Fencing
When you select either iSCSI storage or FibreChannel storage with Web
management-based fencing, the SAN & Fencing tab will refresh and ask
you for configuration information. Enter the appropriate information for
the Remote Management Controller associated with the server that you
used to connect to the Management Console.
NOTE: Later in this procedure the complete matrix configuration will be
exported to the other servers that will be in the matrix. During the
export, Matrix Server will, where possible, use the information
that you specified on the SAN & Fencing tab to configure Web
management-based fencing on the other servers. If a particular
entry on the SAN & Fencing tab did not apply to all servers,
Matrix Server will ask for that information for each of the other
servers.
The Remote Management Controller tab asks for information about the
controllers associated with your servers.