HP StorageWorks EVA Hardware Providers administration guide Windows 2003 (T1634-96052, February 2006)

Verifying installation
To verify installation, perform the following tests. If you have any trouble with installation
or with verifying installation, see “Chapter 4 Troubleshooting in this guide.
Checking the list of programs
A simple way to verify suc cessful installation of the HP H WPs is to make sure they are
listed in the Add/Remove Programs Control Panel in Windows. To see the list of installed
programs, click Windows Sta rt,clickSettings,clickControl Pan el, and double-click
Add/Remove Programs.
You can also check that the hpEVA VSS H ardware Provider is running by making sure it
is listed when you t ype the following at the command line:
vssadm list providers
Checking VDS disk management using DiskRaid
You can install and run the Microsoft DiskRaid command line interface and use the “list
provider
and “list subsystem” commands to verify the HP HWP is working properly.
DiskRaid comes with the Windows 2003 Resource Kit and requires the HP VDS HWP
in order to work with the HP disk array. The example output below shows the use of
these co
mmands:
DISKRAID> List Provider
Prov ###
Name Version
-------
- --------------------------------------------- ----------
* Prov 0
hpEVA VDS Hardware Provider 3.2.0.0
DISKRAID> list subsystem
Subsys ### Name Status Health
---------- ------------------------------ ---------- ----------
Subs
ys 0 HP EVA (SN# 12345) Online Healthy
Checking VSS volume shadow copying
Tes
ting the HP VSS HWP requires a third party application that can work with VSS,
the HP VSS HWP, and the disk array to create hardware volume shadow copies.
42
Installation