HP StorageWorks XP24000 Audit Log User and Reference Guide, v01 (AE131-96003, June 2007)

Detailed information displays for this operation, as shown in the following table.
Table 135 Detailed Info: Drive Interrupt Operation
DescriptionItem
The mounting location of the PDEV.PDEV
Maintenance - Size Change Operation
user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00,[Maintenance],Size Change,,Normal end,,,
Seq.=xxxxx
+PCB=[CACHE-2CB],Num. of PCBs=1
+SIZE=4096
+{Battery,Define}=[{BATTERY-12/BATTERY-22,Install}],Num. of Battery Pairs=1
[Maintenance]
Maintenance function
Size Change
Size Change operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in the following table.
Table 136 Detailed Info: Size Change Operation
DescriptionItem
The mounting location of the PCB (cache memory - CM) to be replaced.PCB
The number of PCBs to be replaced.Num. of PCBs
The capacity of cache memory.SIZE
The mounting location of the battery to be replaced. Not output when no batteries are
installed or uninstalled.
Battery
Indicates the installation or uninstallation of a battery. Not output when no batteries are
installed or uninstalled.
Define
Install: Installation of a battery, Uninstall: Uninstallation of a battery
The number of batteries to be installed or uninstalled.Num. of Battery
Pairs
XP24000 Audit Log User and Reference Guide 149