HP StorageWorks XP24000 Audit Log User and Reference Guide, v01 (AE131-96003, June 2007)

Information - Threshold Value Operation
Example 1
user-name,xx,YYYY/MM/DD,HH:MM:SS:xx, 00:00,[Information],Threshold Value,Alter,
Normal end,,,Seq.=xxxxx
+Type=7days
+{Mechanical error(Recovered,Unrecd.),Media error(Recovered,Unrecd.),
Read/Write error(Recovered,Unrecd.),Drive I/F error(Recovered,Unrecd.),
Controller hardware error(Recovered,Unrecd.),FC I/F error Port 0(Unrecd.),
FC I/F error Port 1(Unrecd.),Prot 0 error(Unrecd.),Port 1 error(Unrecd.)}
={(150,60),(0,15),(150,30),(150,6),(150,6),6,6,12,12}
++PDEV=[HDDR00-01,HDDR00-02,(snip)],Num. of PDEVs=1152
Example 2
user-name,xx,YYYY/MM/DD,HH:MM:SS:xx, 00:00,[Information],Threshold Value,Error Reset,
Normal end,,,Seq.=xxxxx
+PDEV=HDDR00-01
[Information]
Information function
Threshold Value
Threshold Value operation
Alter and Error Reset
Alter is the selected parameter for example 1 and Error Reset is the selected parameter for example
2. This operation uses the parameters shown in the following table.
Table 31 Parameters: Threshold Value Operation
DescriptionParameter
Change the threshold of failed PDEV (physical device).Alter
Indicates Error Reset.Error Reset
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in the following table.
Table 32 Detailed Info: ORM Value Operation (Example 1)
DescriptionItem
The period of time to acquire the result of threshold diagnosis using the read diagnosis
function.
Type
XP24000 Audit Log User and Reference Guide 65